Summary0006647: Button "show complete execution history" raises form validation - WHEN CUSTOM FIELDS EXIST
DescriptionIt seems that the function "Show complete execution history" validates custom fields (which don't have to be filled for viewing the execution history)
Steps To ReproducePrecondition: Testcases have required custom fields

1. Select a test case in the tree (Test Execution Window)
2. Click on "Show complete execution history)
==> An validation error appears on the first custom field saying "This field is required"
TagsNo tags attached.
Database (MySQL,Postgres,etc)MySQL
BrowserChrome Version 37.0.2062.124 m (64-bit)
PHP Version
TestCaseID
QA Team - Task Workflow StatusTBD
Attached Filesjpg file icon 0006647.jpg [^] (34,566 bytes) 2014-10-07 07:22

- Relationships

-  Notes
(0021861)
fman (administrator)
2014-10-06 14:28

please provide really detailed steps to reproduce
(0021868)
tfroehlich (reporter)
2014-10-07 07:21

1. Go to "Define Custom Fields"
2. Click "Create"
3. Enter following data (
      Name: mycustomfield,
      Label: MyCustomField,
      Available for: TestCase,
      Type: string,
      Enable on: TestExecution)
4. Assign this custom field to Test Project
5. Set Checkboxes "Required" and "Active"
6. Click "Update active and required"
7. Go to "Test Specification"
8. Create a Test Suite and a Test Case (no content needed)
9. Create a Testplan and a Build
10. Add Test Case from step 8 to Testplan
11. Go to "Test Execution" and change execution result of the Test Case
    (You have to fill the custom field)
12. Now select the Test Case again
13. Click on "Show complete execution history"

==> Now an error hint appears over the custom field (see attached image)
Displaying of complete history or only last run can only be switched if the custom field is not empty. But it makes no sense to fill the custom field for viewing only.

Can be reproduced with Chrome, IE and Firefox
(0022586)
Laurent_Cabot (reporter)
2015-01-29 15:52

Exactly the same behavior is detected in version 1.9.8.
Workaround: just remove the "Required" and "Active" (uncheck boxes)
Update and the problem has passed away !

- Issue History
Date Modified Username Field Change
2014-10-06 11:19 tfroehlich New Issue
2014-10-06 14:15 fman QA Team - Task Workflow Status => TBD
2014-10-06 14:15 fman Summary Button "show complete execution history" raises form validation => Button "show complete execution history" raises form validation - WHEN CUSTOM FIELDS EXIST
2014-10-06 14:15 fman Steps to Reproduce Updated View Revisions
2014-10-06 14:28 fman Note Added: 0021861
2014-10-07 07:21 tfroehlich Note Added: 0021868
2014-10-07 07:22 tfroehlich File Added: 0006647.jpg
2015-01-29 15:52 Laurent_Cabot Note Added: 0022586



Copyright © 2000 - 2019 MantisBT Team